EU GMP Annex 1 (clause 9.24) asks for continuous viable air monitoring in grade A for the full duration of critical processing, including equipment assembly. This issue compares active air sampling and settle plates in two tests.

The tests

In the first test an AIRBIO TRIO sampled 100 l/min in three one-hour sessions (6,000 litres per session), while three settle plates stayed open for one hour each.

025507510026110:0055211:00811512:00CFU

Active samplingSettle plate

Chart: CFU in the first test, session by session. 3-hour total: 162 with active sampling, 18 with the settle plate (Gazette data)

In the second test a single settle plate on the TRIO.SETTLE floor stand stayed open for three hours next to the three plates of the active sampler. The document reports 162 CFU for active sampling and 23 for the settle plate.

Two different measurements

Active sampling counts the microorganisms in a known volume of air, usually 1 m³. A settle plate counts what lands on its surface. In a closed space such as an isolator, people do not affect the result; with operators present, their movements make deposition on the agar uneven.

Across the two tests, settle plates counted 86% to 89% fewer CFU. The Gazette says the choice of method belongs in the contamination control strategy (CCS), with its reasons.

Results at a glance

  • First test: 162 CFU with active sampling, 18 with settle plates (89% fewer).
  • Second test: 162 CFU against 23 on a single plate left open for three hours (86% fewer).

The Gazette also notes that the settle plate method cannot be validated. For a real evaluation it recommends active sampling, and asks for these data to be taken into account in the contamination control strategy.

Grade A in 2024

  1. Gazette, JanActive or settle plates
  2. Gazette, MarTwo heads
  3. Release, NovShifts of 3, 6 or 9 hours
  4. Gazette, Nov2 and 3 heads
  5. Release, DecFilling lines and isolators
  6. Release, DecModels for the cleanroom
Six pieces on continuous monitoring and multi-head samplers

The Gazette in 2024

  1. JanActive or settle plates in grade A
  2. FebWhere to sample in a cleanroom
  3. MarWhy two heads
  4. AprAIRBIO ONE RAPID-VIRUS
  5. MayThe sterile Daily Shift head
  6. JunThe risk of bioaerosols
  7. JulA short course in microbiology
  8. AugCleanroom tips
  9. SepHow to enter a cleanroom
  10. OctDetecting viruses fast
  11. Nov2- and 3-head samplers
  12. DecActive or passive?
Twelve issues, one a month, all available as PDF

TRIO.BAS in 2024

12issues of The Gazette
4technical releases
9events
8countries
  1. JanuaryThe Gazette restarts with grade A
  2. FebruarySales staff at Villa Cella
  3. AprilExpoFarma, Mexico
  4. AprilKorea Lab, South Korea
  5. MayCleanroom Technology Conference, UK
  6. JuneAFI Symposium, Rimini
  7. OctoberRelease: active or passive?
  8. OctoberIran Pharma, Tehran
  9. OctoberPharma Microbiology, Sofia
  10. OctoberWorkshop in Anápolis, Brazil
  11. NovemberRelease: continuous monitoring in grade A
  12. DecemberRelease: models for the cleanroom
A Gazette every month, nine events in eight countries

The year in review is in the June 2025 news.

Associations we are members of

  • S.I.M.A. (Società Italiana di Microbiologia Applicata)
  • ASCCA (Associazione per lo Studio e il Controllo della Contaminazione Ambientale)
  • PDA (Parenteral Drug Association)
  • A3P Association
  • ISPE (International Society for Pharmaceutical Engineering)