Glossary of air monitoring

The words of microbial and particle monitoring, explained simply: sampling, plates, controlled environments, standards and data integrity.

  • 67terms
  • 7areas
  • 67questions in the FAQ
01

Sampling

How air is collected, and with which instruments.

Passive sampling / settle plates

Plates left open in the environment, on which microbial particles settle by gravity. Simple, but less quantitative than active sampling.

Air flow (l/min)

The amount of air the instrument aspirates every minute, in litres per minute (for example 100 l/min or 200 l/min).

Aspirating head

The perforated part of the sampler through which the air passes before hitting the culture medium. It can be stainless steel, to be sterilised, or sterile and single-shift.

Satellite

A sampling unit connected by cable to a command unit or a PC. Several satellites cover several points at the same time, for example along an isolator line.

02

Particles

What a particle counter counts, and how to read the result.

Micron (µm)

The unit used for particle size. 1 µm is one millionth of a metre.

See also

Mass concentration (µg/m³)

The weight of the particles in one cubic metre of air, in micrograms. It is the format used for indoor air quality, next to the particle count.

Bioaerosol

Particles of biological origin suspended in air: bacteria, mould spores, viruses, cell fragments. They often travel on dust particles or droplets.

03

Microorganisms

What grows on the plates, and how it is counted.

Microorganism

A general term for bacteria, yeasts, moulds and other microscopic organisms.

Bacteria

Single-celled microorganisms, often responsible for infections or product spoilage.

Yeasts

Single-celled fungi that can cause fermentation or spoilage of food and beverages.

Moulds

Multicellular filamentous fungi that form “fuzzy” colonies and may produce spores.

Fungi

The group that includes yeasts and moulds.

Spores

Resistant forms of moulds and some bacteria. They withstand heat, dryness and many disinfectants, which is why they are a benchmark for sterilisation processes.

CFU (colony forming unit)

A visible colony that develops on a plate after incubation. One CFU comes from at least one viable microorganism that has multiplied.

04

Media and plates

The support on which colonies grow.

Culture plate

A plate (Petri or contact) filled with culture medium.

Petri dish

A round plate, usually 90 mm in diameter, used to culture microorganisms.

Contact plate

A smaller plate (about 55 mm), used for surface sampling and in some cases for air sampling.

TSA (Tryptic Soy Agar)

A general-purpose medium for the total bacterial count.

SDA (Sabouraud Dextrose Agar)

A medium used mainly for the growth of yeasts and moulds.

See also
05

Controlled environments

Cleanrooms, isolators and what keeps the air clean.

Cleanroom

A room in which the concentration of airborne particles is kept under control, with filtered air, regulated pressure and procedures for people and materials.

Compressed air and process gases

Air, nitrogen, carbon dioxide or argon that come into contact with the product. They are checked with an active sampler and a dedicated accessory, according to ISO 8573-7.

ATEX

The European rules on equipment for potentially explosive atmospheres. Only an ATEX-certified instrument may be used in those areas.

06

Processes and results

From the incubated plate to the trend, through cleaning and calibration.

Contamination

The unwanted presence of microorganisms in air or on surfaces, products or equipment.

Sterilisation

A process that eliminates all forms of microbial life, spores included. It goes further than disinfection.

VHP (vaporised hydrogen peroxide)

A decontamination agent used in isolators and rooms. It acts in vapour form, including on the outer surfaces of instruments.

Alert limit

A value that signals a possible drift from normal conditions. It does not stop the process, but calls for a check.

Action limit

A value beyond which action is needed: investigation, corrective measures and documentation of the non-conformity.

Trend analysis

Reading results over time. It shows a gradual worsening even when each single result stays within the limits.

Calibration

Comparing the instrument flow rate with a known reference, with a certificate stating the deviation. For an active sampler it is done every 12 months, every 6 with heavy use.

Adjustment

The action that brings the instrument back within specification after calibration, when the deviation is too high.

07

Standards, quality and data

The references that govern monitoring and data handling.

ISO

International standards that set requirements, for example for cleanrooms, compressed air and instruments.

ISO 14644-1

The standard that classifies cleanroom air cleanliness by particle concentration for each size.

Contamination Control Strategy (CCS)

The document in which the manufacturer describes how it prevents, detects and controls contamination across the plant. EU GMP Annex 1 requires it.

USP (United States Pharmacopeia)

The US pharmacopoeia, with chapters on microbiological control and environmental monitoring (for example <1116>).

GMP (Good Manufacturing Practice)

Rules on how to manufacture medicinal and other products under control, with every step documented.

Data integrity

The principle that data must be complete, correct, traceable and not manipulated.

Audit trail

The automatic record of who did what, and when, on each piece of data. It makes any change traceable.

Need more than a definition?

The FAQ has 67 answers on sampling, instruments, calibration and service. For anything else, there is our technical office.

Go to the FAQ → Write to the technical office →

Associations we are members of

  • S.I.M.A. (Società Italiana di Microbiologia Applicata)
  • ASCCA (Associazione per lo Studio e il Controllo della Contaminazione Ambientale)
  • PDA (Parenteral Drug Association)
  • A3P Association
  • ISPE (International Society for Pharmaceutical Engineering)