Microbial Air Monitoring (MAM)
Microbiological monitoring of the air: checking how many and which microorganisms are present in the air of an environment.
Glossary
The words of microbial and particle monitoring, explained simply: sampling, plates, controlled environments, standards and data integrity.
0 terms found
Most searched
No term for this search. Try the FAQ, or write to us. Go to the FAQ →
How air is collected, and with which instruments.
Microbiological monitoring of the air: checking how many and which microorganisms are present in the air of an environment.
Sampling with an instrument that aspirates a known volume of air and impacts it onto an agar plate. It measures how many viable microorganisms are in the air.
Plates left open in the environment, on which microbial particles settle by gravity. Simple, but less quantitative than active sampling.
The amount of air the instrument aspirates every minute, in litres per minute (for example 100 l/min or 200 l/min).
The amount of air drawn in one cycle, in litres. It is chosen according to the expected load, so the plate stays easy to count, and the result is then expressed per 1,000 litres, that is per cubic metre.
Active sampling that runs for the whole critical operation without breaks. EU GMP Annex 1 requires it in Grade A.
The perforated part of the sampler through which the air passes before hitting the culture medium. It can be stainless steel, to be sterilised, or sterile and single-shift.
A sampling unit connected by cable to a command unit or a PC. Several satellites cover several points at the same time, for example along an isolator line.
What a particle counter counts, and how to read the result.
An instrument that counts non-viable particles in the air (dust, fibres), without saying whether they carry live microorganisms.
Particles carrying live microorganisms that can grow on a culture medium.
Inert particles (dust, fibres) that do not grow in culture.
The unit used for particle size. 1 µm is one millionth of a metre.
A size threshold of a particle counter. The instrument counts particles equal to or larger than that size, for example 0.5 µm or 5.0 µm.
The weight of the particles in one cubic metre of air, in micrograms. It is the format used for indoor air quality, next to the particle count.
Particles of biological origin suspended in air: bacteria, mould spores, viruses, cell fragments. They often travel on dust particles or droplets.
What grows on the plates, and how it is counted.
A general term for bacteria, yeasts, moulds and other microscopic organisms.
Single-celled microorganisms, often responsible for infections or product spoilage.
Single-celled fungi that can cause fermentation or spoilage of food and beverages.
Multicellular filamentous fungi that form “fuzzy” colonies and may produce spores.
The group that includes yeasts and moulds.
Resistant forms of moulds and some bacteria. They withstand heat, dryness and many disinfectants, which is why they are a benchmark for sterilisation processes.
A visible colony that develops on a plate after incubation. One CFU comes from at least one viable microorganism that has multiplied.
The support on which colonies grow.
A solid or liquid nutrient mixture that lets microorganisms grow.
A plate (Petri or contact) filled with culture medium.
A round plate, usually 90 mm in diameter, used to culture microorganisms.
A smaller plate (about 55 mm), used for surface sampling and in some cases for air sampling.
A general-purpose medium for the total bacterial count.
A medium used mainly for the growth of yeasts and moulds.
The water loss of the agar during long aspiration. A dried medium makes microorganisms grow poorly and makes counts unreliable.
Cleanrooms, isolators and what keeps the air clean.
A room in which the concentration of airborne particles is kept under control, with filtered air, regulated pressure and procedures for people and materials.
The classes of clean areas in sterile medicine manufacturing under EU GMP Annex 1. Grade A is the zone for the highest-risk operations, B is its background, C and D serve less critical stages.
A closed enclosure that fully separates the process from the room and the operator, who works through gloves. It is decontaminated with automatic cycles.
Restricted Access Barrier System: a barrier with limited access around the critical zone, with unidirectional airflow and gloves for interventions.
Filtered air moving at uniform speed in one direction, carrying particles away from the critical zone. The sampler must not disturb it.
A high-efficiency filter that retains almost all particles. It is used in cleanroom air systems and on the exhaust air of instruments.
Air, nitrogen, carbon dioxide or argon that come into contact with the product. They are checked with an active sampler and a dedicated accessory, according to ISO 8573-7.
The European rules on equipment for potentially explosive atmospheres. Only an ATEX-certified instrument may be used in those areas.
From the incubated plate to the trend, through cleaning and calibration.
The period during which plates are kept at a controlled temperature so that microorganisms form visible colonies.
The unwanted presence of microorganisms in air or on surfaces, products or equipment.
A chemical or physical treatment that reduces or eliminates microorganisms on surfaces and equipment.
A process that eliminates all forms of microbial life, spores included. It goes further than disinfection.
A device that sterilises with pressurised steam. For a stainless steel head, the typical cycle is at 121 °C.
A decontamination agent used in isolators and rooms. It acts in vapour form, including on the outer surfaces of instruments.
A value that signals a possible drift from normal conditions. It does not stop the process, but calls for a check.
A value beyond which action is needed: investigation, corrective measures and documentation of the non-conformity.
Reading results over time. It shows a gradual worsening even when each single result stays within the limits.
Comparing the instrument flow rate with a known reference, with a certificate stating the deviation. For an active sampler it is done every 12 months, every 6 with heavy use.
The action that brings the instrument back within specification after calibration, when the deviation is too high.
The references that govern monitoring and data handling.
International standards that set requirements, for example for cleanrooms, compressed air and instruments.
The standard that classifies cleanroom air cleanliness by particle concentration for each size.
The standard for calibrating light-scattering airborne particle counters for clean spaces.
The European standard on biocontamination control in cleanrooms and controlled environments.
The annex of the EU GMP on the manufacture of sterile medicinal products. It sets the grades of clean areas and requires continuous monitoring in Grade A.
The document in which the manufacturer describes how it prevents, detects and controls contamination across the plant. EU GMP Annex 1 requires it.
Pharmaceutical Inspection Co-operation Scheme: the co-operation between pharmaceutical inspection authorities of many countries, with its own GMP guide.
The US pharmacopoeia, with chapters on microbiological control and environmental monitoring (for example <1116>).
The chapter of the US Pharmacopeia on sterile compounding in pharmacy, including air monitoring.
Rules on how to manufacture medicinal and other products under control, with every step documented.
The principle that data must be complete, correct, traceable and not manipulated.
The key data integrity requirements: Attributable, Legible, Contemporaneous, Original, Accurate. MAM data must meet them too.
ALCOA extended with four more requirements: complete, consistent, enduring and available. These are the nine data requirements used by FDA, MHRA, PIC/S and WHO.
The US FDA rules on electronic records and signatures: personal access, audit trail and electronic signature.
The automatic record of who did what, and when, on each piece of data. It makes any change traceable.
The document that describes step by step how to carry out a task, such as sampling, in a repeatable way.
Checks that the instrument is installed correctly.
Checks that the instrument works to its specifications under controlled conditions.
Checks that the instrument, used in the real process, gives adequate and reproducible performance.
The FAQ has 67 answers on sampling, instruments, calibration and service. For anything else, there is our technical office.