Digitalising the passive method
The passive method, a 90 mm Petri dish exposed to the air for a given time, is still done by hand, without paperless instruments or standardisation. It can now be digitalised at limited cost.
How it works
Application note n.133 shows how to use a standard TRIO.BAS air sampler with the settle stand.
- 1. IdentifyThe TRIO.BAS sampler identifies the plate and records the data
- 2. ExposePlate on the stand, with timer and a place for the lid
- 3. IncubateAfter exposure, the plate goes to the incubator
- 4. CountThe counted CFU are entered in the TRIO.BAS sampler
- 5. ReportSingle or cumulative report; optional photo of each plate
Two options
| Simple method (without camera) | Complete method (with camera) |
|---|---|
| TRIO.BAS air sampler (code 212) | TRIO.BAS air sampler (code 212) |
| BAS software (code 296) | BAS software (code 296) |
| TRIO.SETTLE plate stand (code 367 or 368) | TRIO.SETTLE plate stand (code 367 or 368) |
| CFU photo camera (code 337) |
The investment
The investment can be amortised in one year with the simple method and in two years with the complete method. With the photo, the cfu can be counted by one operator instead of the two requested by the inspector, and the final report saves paper transcription and possible errors. The stand also makes the passive method standard.

The 12 steps of application note n.133
- Preparation of AIR.BIO MONO and the SETTLE system.
- Identification of the culture plate.
- Identified plate placed on top of the SETTLE system.
- Identification data transferred to the SETTLE system.
- Lid removed from the culture plate.
- Lid placed in the lower part of the SETTLE.
- Exposure time set on the SETTLE (for example 4 hours).
- Sampling started with AIR.BIO.
- Lid back on the plate at the end of exposure.
- Plate moved to the incubator.
- Sampling data sent to the PC.
- Photo of each plate sent to the PC.
Passive sampling in ORUM news
- 2023Active and passive for Annex 1
- 2024Active or passive?
- Apr 2025Passive goes digital
- Nov 2025TRIO.SETTLE
What was new in 2025
- AprilDigital passive sampling
- NovemberTRIO.SETTLE
- 1 DecemberGENIUS System
- 2 DecemberCONT.AIR
TRIO.BAS in 2025
8issues of The Gazette
5press releases
5events
4countries
- JanuaryThe Gazette: why more heads
- FebruaryTRIO.BAS on top of Kilimanjaro
- MarchThe Gazette with the Daily Shift video
- AprilThe passive method goes digital
- JuneThe 2024 review
- AugustTRIO.BAS MONO and EN 17141
- SeptemberThe French distributor in Milan
- SeptemberAnalitica Latin America, São Paulo
- SeptemberKorea Life Science, Seoul
- NovemberDistributors in Milan for three days
- NovemberTRIO.SETTLE
- DecemberGENIUS System and CONT.AIR
In 2026 ORUM INTERNATIONAL turns 50.