EU GMP Annex 1: how much air an agar plate can take
ORUM INTERNATIONAL presented an impartial study on the effect of continuous monitoring on agar plates from different international producers.
The study compared 90 mm plates from four media suppliers to find the maximum volume of air a sampler can draw without the plate losing fertility. Air hitting the agar surface dries it, and micro-organisms then grow with more difficulty.
Conclusions
- A 90 mm Petri dish should contain at least 30 ml of medium.
- The total volume of air drawn should be 4,500 litres, that is 3 hours of continuous work.
According to the press release, this check is required by the new EU GMP Annex 1 (2022 edition) and every pharmaceutical company should run it as part of its quality risk assessment. The SOP with the test protocol is available from ORUM INTERNATIONAL.

At 25 litres per minute, 4,500 litres is exactly 3 hours: the flow rate of the new RABS ISOLATOR CM and AIR.BIO TRIO 25 CM.
Annex 1 in the 2023 news
- JanuaryApplication notes and SOPs
- MayActive and passive sampling
- MayAGC, Annex 1 compliant
- SeptemberHow much air a plate can take
- SeptemberRABS ISOLATOR CM
- SeptemberAIR.BIO TRIO 25 CM
- NovemberThe Farmespaña Industrial article
TRIO.BAS in 2023
- JanuaryVERITEST SYSTEM for flow-rate checks
- JanuaryThe P.A.C.A.S. protocol
- JanuaryApplication notes and SOPs for Annex 1
- FebruaryAGC, three tests with one instrument
- FebruaryAIRBIO ONE RAPID-VIRUS
- February-MayFour BAG LINE bags
- MayActive and passive together, as Annex 1 asks
- JuneThe Microbytes interview
- JulyThe Asia tour: China and South Korea
- SeptemberAIR.BIO TRIO and the new three-head samplers
- SeptemberThe agar plate study
- NovemberService technicians at Villa Cella