PDA 2019: one aspirating head or three?
At the PDA pharmaceutical microbiology meeting in Rockville, Maryland, the poster “Evaluation of One Aspirating Head Versus Three Aspirating Heads Using a Microbial Air Sampler in a Sterile Medical Product Manufacturing Area” was presented.
The authors are R. Ligugnana, A. Ligugnana, K. Spallino, A. Klavins, R. Malherbe, A. Hsiung and J. Hardy, of ORUM INTERNATIONAL and Hardy Diagnostics. The study suggests that in a sterile medical product manufacturing area a three-head sampler such as TRIO.BAS TRIO gives more accurate results than a single-head one.
Why use a two- or three-head sampler
- two or three different media at once (e.g. TSA and SDA): time saving;
- two or three identical media at once (e.g. TSA): better statistical evaluation;
- two or three media for continuous cleanroom monitoring: less risk of operator contamination during preparation, as the authorities require;
- two or three identical media for “at rest” and “in operation”, as the authorities require;
- two or three media for the cleanroom Contamination Recovery Rate (CRR) according to USP;
- one unit instead of two or three: space saving in the cleanroom;
- two or three media at once: lower cost of operator time.
Quite often the winning point is the lower cost of operator time.


The full poster can be downloaded as a PDF from the box at the side. For more information: contact us.
Microbiological Environmental Laboratory: Villa Cella and Around Lab News.
What the Contamination Recovery Rate is
USP chapter ‹1116› defines it as the rate at which environmental samples are found to contain any level of contamination. It counts how many plates show growth, not how many CFU each one carries.
The 2019 studies
- JuneASM Microbe: air in museums
- JulyASCCA News: sampling plans
- OctoberPDA: one head or three
- NovemberRapid Microbiology covers the study
TRIO.BAS in 2019
- JanuaryRABS ISOLATOR in Cleanroom Technology
- AprilMilar symposium, Buenos Aires
- AprilKorea Lab, with Microgiene
- MayCleanroom Technology Conference, Birmingham
- JunePUNMICRO partners in Shanghai
- JuneASM Microbe poster: air and works of art
- JulyAIRBIO DUO is launched
- AugustDaily Shift versus the stainless head
- OctoberPDA poster: one head or three?
- NovemberQuality Week, Rio de Janeiro
- NovemberSeminar in Cairo
- NovemberFirst time in Romania
Sources: R&D World; Particle Measuring Systems.





